Setra Systems, Inc. - 264(Very Low Pressure Transducer Setra Systems, Inc.

264 Very Low Pressure Transducer

Download

To place an order

Ask for an offer

Scroll down Find out more

Features

  • Up to 10 PSI Overpressure (Range Dependent)
  • Installation Time Minimized with Snap Track Mounting and Easy- To- Access Pressure Ports and Electrical Connections
  • 0 to 5 VDC or 2-wire 4 to 20 mA Analog Outputs Are Compatible with Energy Management Systems
  • Reverse Wiring Protection
  • Internal Regulation Permits Use with Unregulated DC Power Supplies
  • Fire Retardent Case (UL 94 V-0 Approved)
  • Meets CE Conformance Standards

Applications

  • Heating, Ventilating and Air Conditioning (HVAC)
  • Energy Management Systems
  • Variable Air Volume and Fan Control (VAV)
  • Environmental Pollution Control
  • Lab and Fume Hood Control
  • Oven Pressurization and Furnace Draft Controls

Setra Systems 264 pressure transducers sense differential or gauge (static) pressure and convert this pressure difference to a proportional electrical output for either unidirectional or bidirectional pressure ranges. The 264 Series is offered with a high level analog 0 to 5 VDC or 4 to 20 mA output.

Used in Building Energy Management Systems, these transducers are capable of measuring pressures and flows with the accuracy necessary for proper building pressurization and air flow control.

 The 264 Series transducers are available for air pressure ranges as low as 0.1 in. W.C. full scale to 100 in. W.C. full scale. Static standard accuracy is ±1.0% full scale in normal ambient temperature environments, but higher accuracies are available. The units are temperature compensated to 0.033% FS/°F thermal error over the temperature range of 0°F to +150°F.

 The Model 264 utilizes an improved all stainless steel micro-tig welded sensor. The tensioned stainless steel diaphragm and insulated stainless steel electrode, positioned close to the diaphragm, form a variable capacitor. Positive pressure moves the diaphragm toward the electrode, increasing the capacitance. A decrease in pressure moves the diaphragm away from the electrode, decreasing the capacitance. The change in capacitance is detected and converted to a linear DC electrical signal by Setra's unique electronic circuit.

 The tensioned sensor allows up to 10 PSI overpressure (range dependent) with no damage to the unit. In addition, the parts that make up the sensor have thermally matched coefficients, which promote improved temperature performance and excellent long term stability.